chemiluminescence

[‚kem·i‚lüm·ə′nes·əns]
(physical chemistry)
Emission of light as a result of a chemical reaction without an apparent change in temperature.

Chemiluminescence

 

luminescence associated with a chemical reaction. Either the reaction products or components excited as a result of energy transfer from the reaction products may emit the light. A special case of chemiluminescence is bioluminescence—for example, the glow of decaying wood or of certain insects and marine animals.

Chemiluminescence may accompany gase-phase, liquid-phase, or heterogeneous reactions. The emission spectrum may lie in the infrared, visible, or ultraviolet region. Chemiluminescence is observed in spontaneous reactions—that is, when reactants are mixed—and in reactions that occur, for example, during an electric discharge, during electrolysis (galvanoluminescence), or upon exposure to light or to ionizing radiation.

Chemiluminescence is an example of the direct conversion of chemical energy into luminous energy. The brightness of chemiluminescence is proportional to the reaction rate and to the efficiency of light production, that is, the number of photons emitted per reaction event. The efficiency of light production approaches 100 percent for the bioluminescence of certain fireflies and approaches 25 percent for reactions in which esters of oxalic acid are oxidized by hydrogen peroxide. In certain reactions (“bright” reactions), the efficiency is about 1 percent; in other cases, it is considerably lower. Therefore, highly sensitive photoelectric equipment is used to detect chemiluminescence, especially in slow reactions.

The study of chemiluminescence makes it possible to solve subtle theoretical problems regarding the elementary event of chemical conversion, the redistribution of energy in reaction products, and the structure of molecules. In addition, reaction rates or the concentrations of substances can be measured (see). Reactions characterized by intense chemiluminescence are used in chemiluminescent light sources, which are activated by the mixing of reactants and yield luminous fluxes of —0.1 lumen per milliliter of solution. Chemiluminescense is the basis for the operation of chemical lasers.

REFERENCES

Vasil’ev, R. F. “Mekhanizmy vozbuzhdeniia khemiliuminestsentsii.” Uspekhi khimii, 1970, vol. 39, issue 6, p. 1130.
Khemiliuminestsentnye metody issledovaniia medlennykh khimicheskikhprotsessov. Moscow, 1966.
Chemiluminescence and Bioluminescence. New York-London, 1973.

R. F. VASILEV

References in periodicals archive ?
The quantitative chemiluminescence cPCR described here was based on the coamplification of parvovirus DNA target original sequences and of competitor sequences differing from the original sequence in a 21-bp mutated sequence.
In the chemiluminescence method this inhibition was detected in the range 0.
Through its patented dry slide and enhanced chemiluminescence technologies, the company has transformed the way that clinical laboratories perform testing.
Table 27: US Historic Review for Immunoassay Systems byProduct Segment - Enzyme Immunoassay Systems, FluorescenceImmunoassay Systems, Chemiluminescence Immunoassay Systems,Radio Immunoassay Systems, and Nephelometric ImmunoassaySystems Markets Independently Analyzed with Annual SalesFigures in US$ Million for Years 2004 through 2009(includes corresponding Graph/Chart) III-19
A field-flow fractionation of cells with chemiluminescence detection.
The global Immunoassays Market, by technology, is further segmented into enzyme immunoassays, fluorescent immunoassays, chemiluminescence immunoassays, radioimmunoassays, and others.
6), gas chromatography-mass spectrometry (7), chromatographic flow systems (8), and chemiluminescence (9-11).
Table 18: World Historic Review for Chemiluminescence
Kricka is also active at the international level; he serves on the International Scientific Program Committee of the International Symposium on Bioluminescence and Chemiluminescence, and was recently appointed Chair of the Committee on Advanced Technologies of the International Federation of Clinical Chemistry (IFCC).
Through the introduction of new LOCI[TM] Advanced Chemiluminescence Technology, the Dimension Vista([R]) 1500 Intelligent Lab System provides clinical laboratories with the capability to run a broad menu of tests, which includes panels for cardiac disease, thyroid disorders, therapeutic drug monitoring, drugs-of-abuse testing, protein testing, and routine and specialty chemistry testing.
According to a new market report published by Transparency Market Research "Immunoprotein Diagnostic Testing Market (Radioimmunoassay, Enzyme Based Immunoassay, Chemiluminescence Assay, Immunofluorescence Assay, Immunoturbidity Assay and Immunoprotein Electrophoresis) - Global Industry Analysis, Size, Share, Growth, Trends and Forecast, 2013 - 2019," the global immunoprotein diagnostic testing market was valued at USD 11.