Flow Measurement Device

 

in physiology, an instrument used for measuring the volume rate of blood flow in a blood vessel (flowmeter) or for measuring expired air flow (pneumotachometer). The volume rate of blood flow, that is, the amount of blood that passes through a cross section of a blood vessel per unit time (milliliters per minute, or ml/min), is usually determined by the linear velocity rate of blood as it passes through a segment of pipe of a known cross section. The linear rate of blood flow, that is, the average velocity of the flow of blood particles in a given section of a blood vessel, is measured in the following ways: (1) by the rate of the movement of an air bubble that is introduced into the blood flow, (2) by the difference in blood pressure at two points that are located before and after a constricted section of the pipe through which the blood is flowing (the pneumotachometer has a similar circuit), (3) by the degree of cooling of the heated junction of a thermocouple or thermistor caused by the flowing blood, (4) by the difference in the rates of dissemination of ultrasound in the blood as the ultrasound moves against or with the blood flow, and (5) by the value of the electrical potential of the blood that moves perpendicularly to the magnetic field of a strong electromagnet. The electrical potential of the blood is comparable to that of an electrolytic conductor.

Other types of flow measurement devices used include blood flowmeters, rotameters, turbine meters, and gas flowmeters.

N. K. SARADZHEV

The Great Soviet Encyclopedia, 3rd Edition (1970-1979). © 2010 The Gale Group, Inc. All rights reserved.
References in periodicals archive ?
This device was then compared with an air flow measurement device which was designed according to ANSI/ASHRAE 51-1999.
The company's FLOWave flow measurement device uses Surface Acoustic Wave (SAW) technology that is based on the wave propagation forms similar to seismic waves, which start from an initial point of excitation and spread along the surface of a solid material.
Eventually a flow cross was introduced to allow a VAV box to be pressure independent to duct pressure, but it was still not a flow measurement device. The pressure transducers that are typically used on VAV boxes have poor accuracy; accuracy is based on full scale (not reading), and drifts over time.
Using a flow measurement device with an accuracy of [+ or -] 1% means the uncertainty in money equals more than $30,000 per hour.
The CentriFeeder[TM] with Integrated Control Valve (ICV) is both a controlled feed device and a mass flow measurement device in a single multi-functioning unit that measures and controls the flow of any dry, free-flowing solid.
Purpose: To assess the reproducibility of QA measurements using the Transonic[R] access blood flow measurement device in individual patients over multiple measures.
Two centuries ago, Italian scientist Giovanni Battista Venturi developed a mass flow measurement device for incompressible fluids based on the characteristic pressure drop that fluids exhibit when accelerated to a higher velocity.
It consists of multiple nozzles for measuring a wide range of flow rates with less error and a speed-controlled turbo fan to control the exit pressure so the pressure of the outlet is maintained at atmospheric pressure that then becomes the same as the original pressure before the flow measurement device is applied.
The long term monitoring and detection of process effects are advantageous for any flow measurement device. Coriolis flowmeters detect the conditions which would compromise measurement stability, induce drift, or could add measurement error.
In the late 1990s, J&W Scientific acquired Humonics, a gas and liquid flow measurement device company, and R&D Separations, a specialized manufacturer of carrier gas purification traps and systems.
The effect of the resistance of the flow measurement device on the airflow through a grille is sometimes accounted for by a K-factor.