fluorometer

[flu̇′räm·əd·ər]
(engineering)
An instrument that measures the fluorescent radiation emitted by a sample which is exposed to monochromatic radiation, usually radiation from a mercury-arc lamp or a tungsten or molybdenum x-ray source that has passed through a filter; used in chemical analysis, or to determine the intensity of the radiation producing fluorescence. Also spelled fluorimeter.

Fluorometer

 

(also fluorimeter), an instrument used for measuring the decay time τ of fluorescence, which is approximately 10–8–10–9 sec. A fluorometer operates on the following principle. During high-frequency modulated excitation of luminescence, the luminescence is modulated at the same frequency as the excitation; however, because of the finite duration of the luminescence emission, the phase of the luminescence modulation lags behind that of the excitation modulation. In the case of excitation that is sinusoidally modulated at a frequency ω and fluorescence that decays exponentially, the phase angle φ = tan–1 (ωτ). The relation between the amplitude A0 of the excitation modulation and the amplitude A of the luminescence modulation is Fluorometer. Thus, to determine τ either φ or the ratio A0/A must be measured. If the decay is not exponential, the same method may be used to establish the mean lifetime of the excited state and to estimate the extent to which the decay is not exponential.

Figure 1. Schematic diagram of a phase fluorometer

The most widely used fluorometers are phase fluorometers, which measure φ (Figure 1). In an optical-excitation phase fluorometer, a light beam from a source (1) is focused on a modulator (2). A portion of the modulated flux is deflected by a semi-transparent plate (3) and enters a photomultiplier (5). The remainder of the flux is focused on a specimen (4) to excite fluorescence, which is deflected to another photomultiplier (6). The phase difference φ between the photoelectric currents from (5) and (6) is measured by means of a phase meter (7). A cathode-ray tube or phase detector (8) serves as the phase indicator. Fluorometers based on electron-beam and X-ray excitation have also been developed.

In an instrument that is more advanced than a fluorometer, luminescence is excited by short light pulses, and the decay curve is recorded directly.

Instruments that are used for luminescence analysis are also called fluorometers, or fluorimeters. Such instruments measure the intensity of luminescence and contain both a source for exciting the luminescence and a photometer.

References in periodicals archive ?
We previously used streptavidin bioconjugates of commercially available long-lifetime fluorescent europium(III) chelate nanoparticles, 107 nm in diameter, to demonstrate detection of individual, biospecifically bound nanoparticle-streptavidin bioconjugates on microtitration well surfaces in an immunoassay with a time-resolved fluorescence microimager and a standard time-resolved microtitration plate fluorometer with a sub-attomole detection limit (10, 13).
Selection of the UV AquaTracka by monitoring authorities has been based on the robust measurements offered by the fluorometer as well as its unparallel sensitivity and full ocean depth capability.
The extended period of incubation provided enough enzyme products to ensure reliable fluorometer readings.
Among the equipment for biosensor-decontamination development is a fluorometer for quantifying the fluorescence from nanoparticles.
The 1420 multilabel counter (Victor[TM]) for time-resolved surface measurement of solid-phase fluorescence, the 1230 Arcus fluorometer for time-resolved measurement of DELFIA enhanced fluorescence in tube format, the 1234 DELFIA fluorometer for time-resolved measurement of enhanced fluorescence in plate format, and DELFIA plate-wash were obtained from Perkin-Elmer Life Sciences, Wallac Oy.
The system must allow extension of compatible fluorometer to determine the basic parameters of chlorophyll fluorescence plants concurrently with gas exchange (not supplied), and must allow easy replacement of universal leaf chamber for chamber specially designed for the measurement of narrow grass leaves and shoots of conifers (also not included) .
com)-- Turner Designs is excited to introduce new optical configurations for the Cyclops-6K Submersible Fluorometer.
Table 19: World 11-Year Perspective for Fluorometer by
The sub product segments analyzed include UV-Vis Spectrophotometer, Fluorometer, Luminometer, Scintillation Counter, and Multimode Readers.
The subject of this contract is the supply of spectrophotometers for measurement of small sample volumes in several configurations, and further mikroobjemoveho fluorospektrometru fluorometer for quantification of dna, rna or protein with a small volume of the sample input for various research programs rmu.
com)-- Enviro-T is an accurate, single-channel fluorometer which installs into a plumbing tee for direct in-line measurements.
announces the new C3 Submersible Fluorometer designed to incorporate up to three optical sensors, temperature and depth.