QMF


Also found in: Acronyms, Wikipedia.

QMF

(Query Management Facility) An IBM fourth-generation language for end-user interaction with DB2.
Copyright © 1981-2019 by The Computer Language Company Inc. All Rights reserved. THIS DEFINITION IS FOR PERSONAL USE ONLY. All other reproduction is strictly prohibited without permission from the publisher.
Mentioned in ?
References in periodicals archive ?
The transmit QMFs comprise two linear-phase non-recursive digital filters which split the frequency band 0 to8000 Hz into two sub-bands: the lower sub-band (0 to 4000 Hz) and the higher sub-band (4000 to 8000 Hz).
Herein, the inert gas plays three major roles: (i) producing the plasma required to sputter the metal from the target, (ii) establishing inert gas condensation of the sputtered material, and (iii) creating pressure gradient between the source chamber and the deposition chamber which introduce the nanoclusters to the deposition chamber through the QMF.
According to the property of Quadrature Mirror Filter (QMF), both analysis and synthesis low and high pass filters that are used for signal decomposition and reconstruction are inverse conjugate of each other, as shown in eq.
Demonstra-se que, caso haja contaminacao da materia-prima com STEC nao O157 (deste estudo), o processamento do QMF nao elimina os microrganismos e a temperatura maxima recomendada pela legislacao nao inibe ou elimina o crescimento bacteriano, mantendo-se o risco a populacao.
Let [H.sub.0](z) and [H.sub.1](z) denote the transfer functions of the low-pass and high-pass filter of the analysis part of the two-channel quadrature-mirror filter (QMF) bank, and let [G.sub.0](z) and [G.sub.1](z) denote, respectively the transfer functions of the low-pass and high-pass filter of the synthesis part.
QMF Global Consultants is a leading international consultancy providing ISO quality assurance services within Bahrain, the wider-GCC, and worldwide recently.
Yousaf Razaq, director at UK-based QMF Global, which has its regional headquarters in Bahrain, congratulated the students for having passed the IRCA-approved lead-auditor course which is considered to be one of the most difficult and grueling in the world of quality.
The mineral assemblages (augite, pigeonite, olivine, plagioclase, magnetite, and ilmenite) show crystallization temperatures around 1200-1000[degrees]C and f[O.sub.2] conditions between NNO and QMF buffers [3].
For this purpose, a quadratic mirror filter (QMF) bank [19] is designed based on the characteristics of the fPCG signals.