RAID 0

(redirected from RAID0)

RAID 0

(Redundant Array of Independent Disks Mode 0) A popular disk or solid state drive (SSD) subsystem that increases performance by interleaving data across two or more drives. Data are broken into blocks, called "stripes," and alternately written to two or more drives simultaneously to increase speed. For example, stripe 1 is written to drive 1 at the same time stripe 2 is written to drive 2. Then stripes 3 and 4 are written to drives 1 and 2 simultaneously and so on. When reading, stripes 1 and 2 are read simultaneously; then stripes 3 and 4 and so on.

Ironically, RAID 0 is a misnomer because there is nothing "redundant." If one drive fails, the entire RAID array fails. See disk striping, RAID 3, RAID 5 and RAID.


Striping for Performance
Widely used for gaming, striping interleaves data across multiple drives for performance. However, there are no safeguards against failure.







RAID 0 Probability of Failure
The more drives in a RAID 0 array, the higher the probability of array failure. For example, if experience tells us that one out of a thousand drives fails in a year, the probability that a 2-drive array will fail in a year is 1 in 500; that a 3-drive array will fail is 1 in 333 and so on.

The formula: if the probability of failure of each of n drives is p for a given period, then the probability of not failing is (1-p). The probability of all drives functioning is (1-p)^n, and the probability that at least one drive will fail, causing the array to fail, is [1-(1-p)^n].
References in periodicals archive ?
Now capable of up to 64GB of HyperX Memory, up to NVIDIA GeForce RTX 2080Ti graphics, up to a 9th Gen Intel Core i9-9900K CPU, Dual SSD w/ RAID0, and liquid cooling, the OMEN Obelisk is ready for anything.
The company is also including support for up to 9th Gen Intel Core i9-9900K CPU on the device with dual SSD w/ RAID0, and the liquid cooling.
The strip ribbon function, which is like the RAID0 technique, makes different disks write different parts at the same time, so it accelerates the speed of writing.
The research found that 79% of RAID0 arrays are recovered within an hour while 93% of RAID5 arrays require 48 hours to complete.
The hardware platform used was composed from an AMD Phenom II X6, 6 cores, 8GB RAM, RAID0 configured hard-disks running KVM as hypervisor and QEMU as a hypervisor interface, an Intel DualCore, 4GB RAM as the storage layer and an AMD C-60 DualCore, 4GB RAM as the management layer.
Storage server configuration storage server CPU Intel[R]Xeon(TM) CPU 3.00GHz Mem 1~4G Ethernet Controller Broadcom BCM5721Gigabit RAID Controller 3Ware 9500-12 SATARAID Disk Subsystem Local 160G + Raid0 12 x 160G Table 2.
It also features two Western Digital Raptor drives set in RAID0 configuration for blazing fast speed as well as a RAID5 array of 1.5TB for the user's data".
RAID0 SSD option for ultra-fast boot and game loading and PCIe SSD+HDD storage options for quick responsiveness and massive storage capacity.
1 x 2.5" HDD +up to Super Raid 4 (2 x NVMe M.2 SSDs by PCIe Gen3 X4 in RAID0)