air-cooled heat exchanger

air-cooled heat exchanger

[′er ‚küld ‚hēt ‚iks′chānj·ər]
(mechanical engineering)
A finned-tube (extended-surface) heat exchanger with hot fluids inside the tubes, and cooling air that is fan-blown (forced draft) or fan-pulled (induced draft) across the tube bank.
References in periodicals archive ?
Specialised services include: automation, high volume hydroblasting at 2,250 HP/1,200 GPM, 40K UHP hydro-cleaning, cutting and surface prep, dry ice blasting, chemical cleaning, pigging, sponge media abrasive blasting with reuse, FINFOAM air-cooled heat exchanger cleaning, combustible dust remediation, hydro- and pneumatic-vacuum excavation, in-situ SCR catalyst cleaning and industrial drone inspections.
Air-Cooled Heat Exchanger-- This Plantweb Insight app recognises abnormal situations in the Air-Cooled Heat Exchanger pertaining to fan vibration, reduced cooling, louver defects and fouling.
A core component of any air-cooled heat exchanger used for cooling natural gas in the compression process, the cooling section comprises a precision-engineered matrix of tubes through which hot compressed gas flows.
* Product includes the liquid ring vacuum pump, motor, coupling drive, base, separator/storage tank, air-cooled heat exchanger, shell and tube after condenser, condensate collector tank, inlet spray nozzles and accessories Optional items include a control panel and a variable frequency drive.
In this study, how nanofluid weight fractions, flow rates, and generated power affect the performance of an air-cooled heat exchanger and pumping power is focused.
Together with an air-cooled heat exchanger for steam condensing, the Flex-Plant 10 provides a net efficiency of nearly 49 percent, making it the most efficient peaking plant technology available today.
Gates Draftguard anti-rotation device prevents belt-driven air-cooled heat exchanger (ACHE) fan drives from "windmilling" when they are idle.
It relies primarily on cooling plant water by outdoor ambient air but inside a sealed, air-cooled heat exchanger with no exposure to the environment, unlike a cooling tower.
A fin fan is an air-cooled heat exchanger used to dissipate heat from a fluid directly into the air.
Request for Proposal are invited for Design, Manufacturing, Supply Inspection, Assembly, Testing, Packaging, Transportation, Installation And Commissioning Of The Air-Cooled Heat Exchanger And Circulation Pump As Per Technical Specification Covered In Part-A And Terms And Conditions Covered In Part-B Of This Tender Document For National Aerosol Facility At IIT, Kanpur Opening date : 25 Dec 2017
has designed and manufactured air-cooled heat exchanger equipment essential to the success of the oil, gas and petrochemical processing industries.
The separated water will then enter an air-cooled heat exchanger made by the Yuba Co.