densitometer

(redirected from densitometric)
Also found in: Dictionary, Thesaurus, Medical.

densitometer

(den-să-tom -ĕ-ter) An instrument for measuring the density of exposure of a photographic emulsion. Densitometers have a light source and photocell to measure the transmission (or reflection) of the sample. They are used in obtaining quantitative measurements from photographic records of spectra, diffraction experiments, etc.

Densitometer

A photometer for measuring the optical density (the opposite of transmittance) of materials.

Densitometer

 

a device for measuring the optical density of developed photographic materials. They are classified according to the method of measurement (direct readout and the comparison principle), the type of light receiver (the eye, a photocell, or a photomultiplier), the type of output data (nonrecording devices and automatic recording devices), and the magnitude of the field being measured (densitometers proper, as compared with microdensitometers, which are sometimes referred to as microphotometers).

In devices with direct readout, a single light beam whose initial strength Φ0 is compared with the strength Φ of the beam after passage through a photosensitive layer is usually used. Devices whose operation is based on the comparison method have two light beams originating from the same source, one of which is the measuring beam and the other is the reference beam. In the most widely used type of photoelectric densitometer, the two beams are directed at two photoelectric receivers that are in a difference-reading circuit (that is, if the strength of the two beams is equal, the signal of the two receivers is zero) or are alternately connected to the same receiver. The difference signal, which is caused by unequal strength of the two beams, is brought to a zero reading with the aid of a variable light attenuator (for instance, a gray photometer wedge) inserted into one of the beams being compared and calibrated in units of optical density D = log Φ0/Φ.

The accuracy of densitometer measurements averages ±0.02 optical density units over the entire measurement range. For the best models the range is 5-6 density units; for relatively simple devices it is 2.5-3.0 density units (transmission coefficients of 10-5-10-6 and 0.003-0.001, respectively). The most typical densitometer models made in the USSR are the DFE-10 nonrecording wedge densitometer with selenium photocells (Dmax = 3.0) and the IFO-451 recording wedge microdensitometer with a photomultiplier, which is capable of measuring optical densities up to 2.5 units.

REFERENCE

Gorokhovskii, Iu. N., and T. M. Levenberg. Obshchaia sensitometriia: Teoriia i praktika. Moscow, 1963.

IU. N. GOROKHOVSKII

densitometer

[‚den·sə′täm·əd·ər]
(engineering)
An instrument which measures optical density by measuring the intensity of transmitted or reflected light; used to measure photographic density.

densitometer

i. An instrument for measuring the density or specific gravity of fuel. Also called a densimeter.
ii. An instrument for measuring the optical density (photographic transmission, photographic reflection, visual transmission, etc.) of a material, generally of a photographic image.

densitometer

A device that calibrates the relative strength of a color using complementary filters. Contrast with colorimeter.
References in periodicals archive ?
Densitometric analyses of at least 3 consecutive experiments in duplicate revealed that compared with HAECs not treated with CRP, binding of eNOS to caveolin-1 was increased 40% and 54% at CRP concentrations of 12.
Band intensities in westerns were quantified by a densitometric scanner and the values normalized against the respective anti-tubulin signal.
In the study, 30 men and 3 women with a mean age of 70 underwent densitometric vertebral fracture assessment with standard left lateral decubitus positioning and right lateral decubitus (reverse) positioning.
The molecular weights corresponding with the band positions were estimated from the densitometric profiles (Figs.
It evaluates densitometric data to determine ink requirements over page zones.
The measurement of percentage body fat mass with Futrex-5000 based on an infra-red densitometric assay is a new method |9~, and has not been validated in elderly people.
Densitometric techniques were applied to quantify the protein band densities (Image J software, USA) and expressed as relative densitometric units of the corresponding [beta]-actin control.
With this technique, IgM Mprotein measurement occasionally yields markedly lower quantities than those obtained with nephelometry or densitometric scan of serum protein electrophoresis on agarose gels (2).
The densitometric value for an individual transcript in a sample lane was normalized to the densitometric value for the 18S ribosomal RNA in the same lane.