densitometer

(redirected from densitometrically)
Also found in: Dictionary, Thesaurus, Medical.

densitometer

(den-să-tom -ĕ-ter) An instrument for measuring the density of exposure of a photographic emulsion. Densitometers have a light source and photocell to measure the transmission (or reflection) of the sample. They are used in obtaining quantitative measurements from photographic records of spectra, diffraction experiments, etc.
Collins Dictionary of Astronomy © Market House Books Ltd, 2006

Densitometer

A photometer for measuring the optical density (the opposite of transmittance) of materials.
Illustrated Dictionary of Architecture Copyright © 2012, 2002, 1998 by The McGraw-Hill Companies, Inc. All rights reserved
The following article is from The Great Soviet Encyclopedia (1979). It might be outdated or ideologically biased.

Densitometer

 

a device for measuring the optical density of developed photographic materials. They are classified according to the method of measurement (direct readout and the comparison principle), the type of light receiver (the eye, a photocell, or a photomultiplier), the type of output data (nonrecording devices and automatic recording devices), and the magnitude of the field being measured (densitometers proper, as compared with microdensitometers, which are sometimes referred to as microphotometers).

In devices with direct readout, a single light beam whose initial strength Φ0 is compared with the strength Φ of the beam after passage through a photosensitive layer is usually used. Devices whose operation is based on the comparison method have two light beams originating from the same source, one of which is the measuring beam and the other is the reference beam. In the most widely used type of photoelectric densitometer, the two beams are directed at two photoelectric receivers that are in a difference-reading circuit (that is, if the strength of the two beams is equal, the signal of the two receivers is zero) or are alternately connected to the same receiver. The difference signal, which is caused by unequal strength of the two beams, is brought to a zero reading with the aid of a variable light attenuator (for instance, a gray photometer wedge) inserted into one of the beams being compared and calibrated in units of optical density D = log Φ0/Φ.

The accuracy of densitometer measurements averages ±0.02 optical density units over the entire measurement range. For the best models the range is 5-6 density units; for relatively simple devices it is 2.5-3.0 density units (transmission coefficients of 10-5-10-6 and 0.003-0.001, respectively). The most typical densitometer models made in the USSR are the DFE-10 nonrecording wedge densitometer with selenium photocells (Dmax = 3.0) and the IFO-451 recording wedge microdensitometer with a photomultiplier, which is capable of measuring optical densities up to 2.5 units.

REFERENCE

Gorokhovskii, Iu. N., and T. M. Levenberg. Obshchaia sensitometriia: Teoriia i praktika. Moscow, 1963.

IU. N. GOROKHOVSKII

The Great Soviet Encyclopedia, 3rd Edition (1970-1979). © 2010 The Gale Group, Inc. All rights reserved.

densitometer

[‚den·sə′täm·əd·ər]
(engineering)
An instrument which measures optical density by measuring the intensity of transmitted or reflected light; used to measure photographic density.
McGraw-Hill Dictionary of Scientific & Technical Terms, 6E, Copyright © 2003 by The McGraw-Hill Companies, Inc.

densitometer

i. An instrument for measuring the density or specific gravity of fuel. Also called a densimeter.
ii. An instrument for measuring the optical density (photographic transmission, photographic reflection, visual transmission, etc.) of a material, generally of a photographic image.
An Illustrated Dictionary of Aviation Copyright © 2005 by The McGraw-Hill Companies, Inc. All rights reserved

densitometer

A device that calibrates the relative strength of a color using complementary filters. Contrast with colorimeter.
Copyright © 1981-2019 by The Computer Language Company Inc. All Rights reserved. THIS DEFINITION IS FOR PERSONAL USE ONLY. All other reproduction is strictly prohibited without permission from the publisher.
References in periodicals archive ?
Deposition of silver on the gold NPs amplifies the absorbance signal, which is recorded densitometrically (Fig.
Blots were analyzed densitometrically with a UVP EC3 bioimaging system with Labworks 4.5 software.
Unlike conventional cemented and non-cemented THR devices, which can lose 20-40% of proximal femoral bone mass within the first 24 months following surgery, Revelation components have been shown densitometrically to preserve original bone (95%+ at two years and 100% at four years) in primary THR surgeries and to regenerate bone in revision THR surgeries.
The band intensities were densitometrically quantified and calculated using ImageJ software version 1.47 (http://imagej.
The bound antibodies were visualized using an enhanced chemiluminescence reagent by ECL kit (RPN2232; GE Healthcare Life Sciences, UK) and quantified densitometrically using Gel-image analyzing system (Gene Gnome, Syngene, USA).
The bands were examined densitometrically using ImageJ, an image analysis system (National Institute of Health, Bethesda, USA).
The reactive bands were detected by chemiluminescence and signal intensity was densitometrically quantitated in Western blotting (Image J, version 2.1.4.7, National Institutes of Health, USA).
After incubation with secondary antibodies, signals were developed for chemiluminescence, visualized by autoradiography, and quantified densitometrically. Results were normalized to betaactin protein (#A5316,1:10000; Sigma-Aldrich, Inc., USA), or to the total form of each phosphorylated protein, and reported as arbitrary units.
The bands were analyzed densitometrically by using a Chemi-doc image analyzer (Bio-Rad, Hercules, CA, USA).
As described by us earlier [19], clear zones of lysis against a blue background indicate gelatinolytic activity and were scanned densitometrically to assess gelatinase activity.
Nuclear abundance of phospho-ERK1/2 was determined densitometrically on micrographs recorded at respective time points with fixed image acquisition settings.