goniometer

(redirected from goniometry)
Also found in: Dictionary, Thesaurus, Medical, Wikipedia.
Related to goniometry: manual muscle testing

goniometer

[‚gō·nē′äm·əd·ər]
(electromagnetism)
An instrument for determining the direction of maximum response to a received radio signal, or selecting the direction of maximum radiation of a transmitted radio signal; consists of two fixed perpendicular coils, each attached to one of a pair of loop antennas which are also perpendicular, and a rotatable coil which bears the same space relationship to the coils as the direction of the signal to the antennas.
(engineering)
An instrument used to measure the angles between crystal faces.
An instrument which uses x-ray diffraction to measure the angular positions of the axes of a crystal.
Any instrument for measuring angles.
McGraw-Hill Dictionary of Scientific & Technical Terms, 6E, Copyright © 2003 by The McGraw-Hill Companies, Inc.
The following article is from The Great Soviet Encyclopedia (1979). It might be outdated or ideologically biased.

Goniometer

 

(1) In physics, an instrument for measuring the angles between the planes of crystals, and also for measuring the angles of various prisms. Crystals can be distinctively characterized by the angles between their facets. Before the discovery of X-ray structural analysis, the method of measuring crystals with a goniometer was the main means of diagnosing crystalline substances. It was later superseded to a considerable degree by X-ray structural analysis.

Goniometers may be of the contact or reflecting types. The simplest contact goniometer consists of a protractor attached

Figure 1. Single-disk reflecting goniometer: (a) overall view; (b) diagram. C is the collimator, T is the viewing tube, L is the limb, ν is the vernier, and N1 and N2 are normals corresponding to facets a and b. to a ruler; it permits measurement of angles with an accuracy of 0.25°-0.5°. A more precise reflecting goniometer is shown in Figure I.

A crystal attached to a rotating axis is illuminated by a collimated beam of light, and the rays reflected from its facets are observed in sequence by looking into a viewing tube T (a single-circle goniometer). The angles of rotation of the crystal are read from a scale. In more advanced two-circle goniometers (developed by Fedorov, Gol’dshmidt, and Chapskii), the crystal or the viewing tube can be rotated about two axes. The precision of measurement is to within l’ to 10’-20’.

REFERENCES

Flint, E. E. Prakticheskoe rukovodstvo po geometricheskoi kristallografii, 3rd ed. Moscow, 1956.
Flint. E. E. Nachala kristallografii, 2nd ed. Moscow, 1961.

M. P. SHASKOL’SKAIA

(2) In anthropology, a goniometer is an instrument for measuring angles of curvature of the spine, the facial angle, the angle of the nose, and so on. A contact goniometer consists of a graduated metal plate in the form of an arc; its ends are joined by a transverse plate with a rotating pointer with a plumb bob attached to its center. The goniometer is attached to dividers (for example, of the sliding type), and the size of the angle being measured is determined by the distance of deflection of the pointer from the vertical.

The Great Soviet Encyclopedia, 3rd Edition (1970-1979). © 2010 The Gale Group, Inc. All rights reserved.

goniometer

i. A direction-finding device commonly used in radio location and radio navigation. It has a fixed antenna, and the direction response is varied electrically. Using a method called phase comparison, it senses the angle between a fixed reference point and the direction from which a radio signal is being received. See automatic direction finder.
ii. A motor-driven instrument used with four stationary aerials to a deliver rotating signal field for VOR (very high frequency omnidirectional radio-range).
An Illustrated Dictionary of Aviation Copyright © 2005 by The McGraw-Hill Companies, Inc. All rights reserved
References in periodicals archive ?
(15) Despite widespread recognition of the importance of range of motion as a critical factor for successful flight in avian patients, very few studies have investigated the use of goniometry measurement in avian species or have established normal reference values.
The current study reported validity and interobserver and intraobserver reliability for universal goniometry compared to 3 alternative measurement methods for elbow goniometry including photography, movie, and a smartphone application.
(2012) evaluated ICC of visual estimation compared to clinical goniometry in 50 elbows.
Measurement of joint motion: a guide to goniometry. Philadelphia: FA Davis; 2009.
Surface polarity, morphology, and roughness are determined using goniometry and AFM.
Goniometry: Using a pipette mounted on a support apparatus (to provide experimental consistency), we placed a 5 L drop of 5 M NaCl aqueous solution on the coating surface.
The corresponding microstructure and mechanical and optical properties of NDPs films were investigated by scanning electron microscope (SEM), atomic force microscopy (AFM), contact angle goniometry, and optical analysis measurements, respectively.
(10) The shoulder's active and passive ROM (flexion, extension, abduction, adduction, and internal and external rotation) were measured via goniometry, (11) and the functional assessment was calculated according to the Constant-Murley scale.
Cram session in goniometry and manual muscle testing; a handbook for students & clinicians.
This test focused on the assessment of motor domains of primitive reflexes, head control, sitting without support, passive and active tone, popliteal angle, and adductor angle hip through the use of goniometry.