photometer

(redirected from luxometer)
Also found in: Dictionary, Thesaurus, Medical.

photometer

an instrument used in photometry, usually one that compares the illumination produced by a particular light source with that produced by a standard source

Photometer

An instrument used for making measurements of light, or electromagnetic radiation, in the visible range. In general, photometers may be divided into two classifications: laboratory photometers, which are usually fixed in position and yield results of high accuracy; and portable photometers, which are used in the field or outside the laboratory and yield results of lower accuracy. Each class may be subdivided into visual (subjective) photometers and photoelectric (objective or physical) photometers. These in turn may be grouped according to function, such as photometers to measure luminous intensity (candelas or candlepower), luminous flux, illumination (illuminance), luminance (photometric brightness), light distribution, light reflectance and transmittance, color, spectral distribution, and visibility. Visual photometric methods have largely been supplanted commercially by physical methods, but because of their simplicity, visual methods are still used in educational laboratories to demonstrate photometric principles. See Illuminance, Luminance, Luminous flux, Luminous intensity

photometer

(foh-tom -ĕ-ter) An instrument used in photometry, such as a CCD, photovoltaic detector, photomultiplier, photodiode, or bolometer. In these devices the incident radiation is converted into an electrical signal whose magnitude can be determined very precisely.

Photometer

An instrument for measuring photometric quantities, such as luminance, luminous intensity, luminous flux, and illuminance.

Photometer

 

an instrument for the measurement of photometric quantities. When a photometer is operated, some spatial restriction is imposed on the radiation flux, which is registered by a radiation detector with a specific spectral sensitivity.

Illuminance is measured with luxmeters, luminance with luminance photometers, and luminous flux and luminous energy with integrating-sphere photometers. The instruments used for measuring the color of an object are called colorimeters. If the eye is used as a detector, the photometer is known as a visual photometer; if a physical detector is used, it is called a physical photometer. The optical assembly of a photometer, sometimes called the photometric head, contains lenses, light-diffusing plates, light attenuators, light filters, diaphragms, and a radiation detector. In photometers with physical detectors, the radiation flux is usually converted into an electrical signal, which is registered by means of a microammeter, voltmeter, or other type of instrument. In flicker photometers, the indicating instruments used are electrometers, storage oscillographs, and peak voltmeters. In a visual photometer the brightnesses of two fields separately illuminated by the luminous fluxes to be compared are equalized by eye through an eyepiece on the photometric head.

The optical designs of photometers (Figure 1) used to determine dimensional photometric quantities provide either a constant geometric factor or a change in the factor according to some specific relationship. The systematic measurement errors of photometers having an absolute calibration are typically large (it is difficult to reduce the error to less than 5 percent). Qualified specialists

Figure 1. Optical diagrams of photometers for the measurement of various quantities: (a) illuminance, exposure, and (with application of the inverse-square law) luminous intensity and luminous pulse emittance, (b) luminous intensity and luminous pulse emittance (by means of a telecentric system), (c) luminance and the integral of a luminance pulse (with use of a focusing optical system), (d) luminance (with use of a calibrated diaphragm); (S) light source, (RD) radiation detector with filters and attenuators to correct spectral sensitivity, (0) objective with focal length f,(D) diaphragm positioned in the focal plane (in b) or in the image plane (in c), (Da) aperture stop, (Dc) calibrated diaphragm, (α) and (β) angular dimensions of the bundles of rays being measured

in well-equipped laboratories are usually able to make measurements with errors of 10–20 percent. Errors in the measurement installation itself may increase the error to 50 percent or more.

The accuracy of photometers used to measure the ratio of radiation fluxes (transmission factors and reflection coefficients) is very high. Such instruments may be constructed with one or two optical channels. Single-channel photometers measure the relative reduction in the radiation flux when a specimen is placed in the path of the rays. In a two-channel photometer the radiation flux is attenuated by the specimen as fluxes in the measuring and reference channels are compared. The fluxes are made equal by means of adjustable diaphragms, photometer wedges, or similar devices. The transmission factors and reflection coefficients of light-diffusing specimens may also be measured by integrating-sphere photometers.

A. S. DOINIKOV

photometer

[fō′täm·əd·ər]
(engineering)
An instrument used for making measurements of light or electromagnetic radiation, in the visible range.

Photometer

An instrument used for making measurements of light, or electromagnetic radiation, in the visible range. In general, photometers may be divided into two classifications: laboratory photometers, which are usually fixed in position and yield results of high accuracy; and portable photometers, which are used in the field or outside the laboratory and yield results of lower accuracy. Each class may be subdivided into visual (subjective) photometers and photoelectric (objective or physical) photometers. These in turn may be grouped according to function, such as photometers to measure luminous intensity (candelas or candlepower), luminous flux, illumination (illuminance), luminance (photometric brightness), light distribution, light reflectance and transmittance, color, spectral distribution, and visibility. Visual photometric methods have largely been supplanted commercially by physical methods, but because of their simplicity, visual methods are still used in educational laboratories to demonstrate photometric principles.

photometer

Any instrument that measures photometric quantities such as luminance, luminous intensity, luminous flux, and illumination.
References in periodicals archive ?
(1) The common luxometer used allowed us to compute gamma values fully equivalent to the ones obtained from photometer measurements.
The explanation of this fact is that, for all the achromatic stimuli, luxometer measurements are equal to photometer measurements multiplied by a constant ("factor" in Tables 1 and 2), and this is also the constant corresponding to the reference white (Yn).
(3) As the "factor" for chromatic stimulus type was different from the achromatic one, luxometer measurements were not accurate when estimating the relative luminance of these stimuli.