temperature error

temperature error

[′tem·prə·chər ‚er·ər]
(engineering)
That instrument error due to nonstandard temperature of the instrument.

temperature error

temperature errorclick for a larger image
Aircraft flying toward high pressure.
temperature errorclick for a larger image
Aircraft flying toward low pressure.
i. A discrepancy in various instruments caused by either the ambient temperature differing from the design limits of the instrument or the temperature variation differing from the one incorporated in the design of the instrument.
ii. A discrepancy arising in an altimeter because the ambient lapse rate differs from one in the standard atmosphere, resulting in a density different from the one calculated. A pressure altimeter indicates higher than true altitude in colder air and lower than true altitude in warmer air.
References in periodicals archive ?
Pilots of aircraft not equipped with an RNAV system capable of temperature compensation must use the ICAO Cold Temperature Error Table found in the AIM at Para.
16: Temperature distribution for case-1 (one-half symmetry), a) ANN model, b) FEA simulation, c) temperature error C[degrees]
The LTC2996 has a guaranteed temperature error [less than or equal to] [+ or -] 1[degrees]C from 0[degrees]C to +100[degrees]C and <[+ or -] 1.
In the differential system, the compensation of temperature error can be best illustrated by (4), which binds the output voltage with the resistance change of all the arms.
Shen, "Study on temperature error processing technique for fiber optic gyroscope," Optik, vol.
Piper N27 Bradford County SEGMENTS Temperature Intermediate Final Missed Appr -21C/-6F X -10C/14F X -18C/0F X -15C/5F X -24C/-11F X COLD TEMPERATURE ERROR TABLE HEIGHT ABOVE AIRPORT IN FEET REPORTED TEMP [degrees]C 200 300 400 500 600 700 800 900 + 10 10 10 10 10 20 20 20 20 0 20 20 30 30 40 40 50 50 -10 20 30 40 50 60 70 80 90 -20 30 50 60 70 90 100 120 130 -30 40 60 80 100 120 140 150 170 -40 50 80 100 120 150 170 190 220 -50 60 90 120 150 180 210 240 270 REPORTED TEMP [degrees]C 1000 1500 2000 3000 4000 5000 + 10 20 30 40 60 80 90 0 60 90 120 170 230 280 -10 100 150 200 290 390 490 -20 140 210 280 420 570 710 -30 190 280 380 570 760 950 -40 240 360 480 720 970 1210 -50 300 450 590 890 1190 1500
It calculates the rate of change in building temperature for one hour periods, using the temperature error (from the set points) to determine the required output from the heating and cooling plant over the next one hour period.
The temperature recorded was that of the sample which will eliminate the temperature error between the furnace and the sample.
Controller 6, Feedback-Compensated Feed-Forward with Optimal Feedback Compensation, (FBCFF), uses the same control as controller 5, but in addition the outlet water temperature is measured, allowing the temperature error to be calculated.
T] = 0,1K and the temperature error of the electronic measuring equipment [[delta].
Distance to Temperature Temperature Error the welding determined with determined by [epsilon] axis [mm] FEM [[degrees]C] thermography [%] [[degrees]C] 0 2970 2993 0,76 4 2588 2900 10,75 8 1723 1800 4,27 12 505 600 15,83 20 56 60 6,66

Full browser ?